How to deal with high temperature of vacuum pump?

Addtime: 2020-07-16 Browse times: 2049

The high temperature problem of vacuum pump has been bothering users. How to solve the problem of high temperature of vacuum pump? Where is the cause of high temperature of vacuum pump? How to solve it? With these problems, we have studied the high temperature problem of vacuum pump. The following is the research content.


Cause analysis of high temperature in vacuum pump

(1) High motor power and high working current lead to high temperature of vacuum pump.

(2) The number of fan blades is less and the air volume is small.

(3) Fan speed is low, air pressure, air volume is small.

(4) The voltage of the bus where the vacuum pump motor is located is 380V. Due to the cable voltage drop and uneven load distribution, the actual voltage applied by the motor is only 365v. The low voltage results in large operating current.

(5) Motor with dust, oil, reduce the heat dissipation capacity, resulting in high temperature vacuum pump.


Countermeasures for high temperature problem of vacuum pump

The motor power and speed are matched with the vacuum pump and cannot be changed. The fan is installed on the main shaft of the motor. The speed of the motor determines the speed of the fan and cannot be replaced. Although increasing the number of fan blades can play a certain role, but the dynamic balance is not easy to find after the number of blades is increased. If the alignment is not good, the motor vibration will increase.

(1) The fan cover of the original vacuum pump was lengthened by 40cm, and an axial fan with the same diameter as the fan cover was installed inside. The motor power of the axial fan was 850W, the speed was 1489r / min, and the voltage was 380V. The original fan remains. The axial flow fan is equipped with another power supply control, and the axial flow fan is not interlocked with the main motor. After the vacuum pump is started, the axial flow fan is started in time, and the axial flow fan is stopped 30 minutes after the vacuum pump is shut down, so that the main motor can be fully cooled;

(2) Regularly remove the dust on the vacuum pump motor to keep the heat sink clean and increase its heat dissipation capacity;

(3) Adjust the bus voltage of vacuum pump to 400V.


Effect of vacuum pump high temperature solution

(1) Due to the high speed of axial flow fan, large air pressure and air volume, the cooling effect is greatly enhanced. Under the same ambient temperature and load current, the temperature of main motor of vacuum pump drops by 12 ℃. In summer, the main motor temperature did not exceed the limit.

(2) The insulation aging speed of the main motor is slowed down and its service life is prolonged.

(3) The axial flow fan can be controlled manually. After the main motor is stopped, the axial flow fan can still operate, which can make the main motor get sufficient cooling.

(4) After adjusting the voltage, the running current of diaphragm pump is reduced to 210a, and the calorific value is relatively reduced.

(5) Try to make the load distribution balance of the two sections of bus to prevent the voltage drop too much due to the overload of a section of bus.

Through the research on the high temperature problem of vacuum pump, we found that the high temperature of vacuum pump is mainly caused by motor heating, so the main way to solve this problem is also around the vacuum pump motor.


Scan QR code and add wechat